Facial Contouring

Orthognathic, Cosmetic and ​reconstructive surgery​

Personalized orbital implants for secondary correction of enophtalmos and craniofacial implants for reconstructive and cosmetic purposes.

Submit a case

Features & Benefits

Orbital floor implant, product render
Optimized fixation

2 holes per segment to prevent dislocation of the implant.

Depending on nerve position, implant location and freedom of access, screw holes are provided in the implant body or lip extensions.

Interlocking Multi-Piece Design

Simplified insertion with precise fit, eliminating the need for intraoperative implant shaping.

The screw positions consider the infraorbital nerve, lacrimal apparatus, bone quantity, and insertion angle.

The multi-piece design minimizes access incisions and helps avoid stretching sensitive nerves.The implants can be connected using an interlocking design, similar to a 3D puzzle.

Material flexibility

Depending on the surgeon’s preference, facial contouring implants can be made in different material.

CNC-milled from PEEK or 3D-printed in titanium.

  • Optimized fixation

    2 holes per segment to prevent dislocation of the implant.

    Depending on nerve position, implant location and freedom of access, screw holes are provided in the implant body or lip extensions.

  • Interlocking Multi-Piece Design

    Simplified insertion with precise fit, eliminating the need for intraoperative implant shaping.

    The screw positions consider the infraorbital nerve, lacrimal apparatus, bone quantity, and insertion angle.

    The multi-piece design minimizes access incisions and helps avoid stretching sensitive nerves.The implants can be connected using an interlocking design, similar to a 3D puzzle.

  • Material flexibility

    Depending on the surgeon’s preference, facial contouring implants can be made in different material.

    CNC-milled from PEEK or 3D-printed in titanium.

One system, many possibilities

  • Orbital wall

    Orbital wall

  • Malar

    Malar

  • Chin

    Chin

  • Jaw

    Jaw

Material flexibility

Depending on the surgeon’s preference, facial contouring implants can be made from different materials.

  • CNC-milled from PEEK

    CNC-milled from PEEK

  • 3D-printed in Titanium

    3D-printed in Titanium

Case report: Correction of Hemifacial Microsomia​

A 26-year-old male was diagnosed with right-sided hemifacial microsomia Pruzansky’s Type IIb. In this case the craniomaxillofacial surgeon decided to use 2 CADskills facial implants to correct the facial asymmetry, instead of the usual facial rotation using orthognathic procedures.​

Read case report